Reliability Assessment of a Solid and Nail-jointed Box-Section African Birch (Anogeissus leiocarpus) Timber Column

Uwemedimo Nyong Wilson, Adedeji A. A., Mohammed I. S., Alomaja J. A., Sani J. E.

Abstract


In an attempt to study the performance of a box-section timber column, a structural reliability analysis was carried out on the Nigerian-grown African birch to ascertain its usability for columns under several axial loads. Samples of the timber were bought, sawn and used to prepare small clear specimens of box columns after which their compressive strengths were obtained. Results of corresponding solid square sections of the same timber specie were used as the control. Some statistical parameters were determined for the deterministic design of the timber column. A FORTRAN-based program was also developed and used for the reliability analysis of the Nigerian-grown African birch columns designed to ascertain their level of safety using First-Order Reliability Method (FORM). From the reliability analysis, both sections were found adequate to support the design load however, it was found out that only beyond 100kN is there an advantage of the box-section above the solid. The compressive capacity of the box-section (150 x 150mm) was found to be 1.5 times that of the solid section and this margin increases to more than two times the solid section as the design load was increased to 1000kN. Also, the box section has a higher capacity to bear its Euler load with a greater length than the solid section because of its greater radius of gyration and rigidity. Therefore the box section would rather be preferable for long columns than the solid section. Lastly, the box-section is also economically advantageous considering the area of the design section- 10,400mm2 over the solid section offering a cross sectional area of 22,500mm2.


Full Text:

PDF

References


Gyrna, F.M., Juran, J.M. (2007). Quality Planning and Analysis: From Product Development.

Harries, K. A., Petrou, M. F. George, B (2000). ‘‘Structural characterization of built-up timber columns.’’ Rep. No. ST99-02, Dept. of Civil and Environmental Engineering, University of South Carolina, Columbia, S.C.

Ireson, W.G., Coombs, C.F. Jr., Moss, R.Y. (1996). Handbook of Reliability Engineering and Management. Second Edition, ISBN-13: 978-0070127500 ISBN-10:0070127506.

Juran, J.M., DeFeo, J.A. (2015). Juran’s Quality Handbook: The Complete guide to performance excellence. 6th Edition, New York: McGraw Hill.

Jimoh, A. A. (2005). Ultimate Design Strength of Axially Loaded Ayin (Anogeissus leiocarpus) Timber Columns. Journal of Applied Science and Technology. 10(1 & 2): 029-034.

Karyadi, Dewi S.M. and Soehardjono A. (2018). The strength of axially loaded square hollow-section column made of laminated asian bamboo (Dendrocalamus asper Becker). Research Journal of Applied Sciences, Engineering and Technology 15(9): 337-343.

Nowak AS, Collins KR (2000).Reliability of Structures, McGraw-Hill Companies, USA. pp. 337.

Peng Shang, Youfu Sun, Dingguo Zhou, Kai Qin, Xiaolin Yang (2018). Experimental study of the bending performance of hollow glulam beams. Journal of wood and fibre science, 50(1): 3-19.

Wilson U.N., Adedeji A.A., Sani J.E., Alomaja J.A. (2018). A Reliability-Based Design of Nigerian-Grown African Birch (Anogeissus leiocarpus) timber on its Compressive Strength. Epistemics in Science, Engineering and Technology. 8(1): 593-598.

Wilson U.N., Adedeji A.A., Oriola F.O.P., Sani J.E., Alomaja J.A. (2019). Comparative Reliability Assessment of a Solid and Nail-jointed I-Section of Nigerian-Grown African Birch (Anogeissus leiocarpus) Timber Column. International Journal of Scientific and Engineering Research. Vol., 10, Issue 4.


Refbacks

  • There are currently no refbacks.